Altronix MAXIMAL7, Access Power Controller w/ Power Supply/Charger
Condition:
* New Surplus Stock, In OEM Packaging. As Pictured.
Additional Notes:
Input
* 115 Volt AC 60 Hz, 4.2 Amp Input.
* Power supply input options:
• a) Two (2) common power input for either ACM8 and lock power (factory installed).
• b) Two (2) isolated power inputs (External Power Supply Is Required), (current is determined by the power supply connected, not to exceed a maximum of 10 Amp total).
* Sixteen (16) Access Control System trigger inputs.
* Input options:
• a) Sixteen (16) normally open (NO) inputs.
• b) Sixteen (16) open collector inputs.
• c) Any combination of the above.
Output
* 24 Volt DC Outputs.
* Maximum output current: 24 Volt DC @ 9.4 Amp
* Sixteen (16) independently controlled outputs.
* Output options:
• a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
• b) Sixteen (16) form "C" 5 Amp rated relay outputs.
• c) Any combination of the above.
* Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5 Amp).
* Filtered and electronically regulated outputs (built-in power supply).
* Thermal and short circuit protection with auto reset.
Fuse Ratings
* Power Supply input fuse rated @ 10 Amp/250 Volt.
* ACM8 boards main fuse is rated at 10 Amp Output fuses are rated @ 3.5 Amp
Features
* Fire Alarm disconnect (latching or non-latching) isindividually selectable for any or all of the sixteen (16) outputs.
* Fire Alarm disconnect input options:
• a) Normally open (NO) or normally closed (NC) dry contact input.
• b) Polarity reversal input from FACP signaling circuit.
* Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 Amp 28 Volt DC).
Supervision
* AC fail supervision (form "C" contacts).
* Notification trigger is selectable for 30 seconds (Factory Set) or 6 hours.
* Low battery and battery presence supervision (form "C" contact).
Battery Charging (Batteries are Sold Separately).
* Capacity: 12AH/12 Volt DC (4 Within Enclosure); 40AH/65AH (Requires Separate Enclosure).
* Type: Sealed lead acid or gel type.
* Failover: Upon AC loss, instantaneous.
Visual Indicators
* Red LEDs indicate outputs are triggered (relays energized).
* Green LED indicates FACP disconnect is triggered.
* AC input and DC output LED indicators.
Electrical
* Temperature:
* Operating: 0°C To 49°C (32°F To 120°F).
* Storage: - 20°C To 70°C ( - 4°F To 158°F).
* Relative Humidity: 85% +/- 5%.
* BTU/Hr. (approx.): 115 BTU/Hr.
* System AC Input VA Requirement: 483 VA.