Altronix MAXIMAL7 Access Power Controller w/ Power Supply/Charger
Condition:
* New surplus stock, in OEM packaging. As pictured.
Additional Notes:
Input
* 115VAC 60Hz, 4.2A input.
* Power supply input options:
• a) Two (2) common power input for either ACM8 and lock power (factory installed).
• b) Two (2) isolated power inputs (external power supply is required), (current is determined by the power supply connected, not to exceed a maximum of 10A total).
* Sixteen (16) Access Control System trigger inputs.
* Input options:
• a) Sixteen (16) normally open (NO) inputs.
• b) Sixteen (16) open collector inputs.
• c) Any combination of the above.
Output
* 24VDC outputs.
* Maximum output current: 24VDC @ 9.4A.
* Sixteen (16) independently controlled outputs.
* Output options:
• a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
• b) Sixteen (16) form "C" 5A rated relay outputs.
• c) Any combination of the above.
* Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 2.5A).
* Filtered and electronically regulated outputs (built-in power supply).
* Thermal and short circuit protection with auto reset.
Fuse Ratings
* Power Supply input fuse rated @ 10A/250V.
* ACM8 boards main fuse is rated at 10A. Output fuses are rated @ 3.5A.
Features
* Fire Alarm disconnect (latching or non-latching) isindividually selectable for any or all of the sixteen (16) outputs.
* Fire Alarm disconnect input options:
• a) Normally open (NO) or normally closed (NC) dry contact input.
• b) Polarity reversal input from FACP signaling circuit.
* Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
Supervision
* AC fail supervision (form "C" contacts).
* Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
* Low battery and battery presence supervision (form "C" contact).
Battery Charging (Batteries are sold separately).
* Capacity: 12AH/12VDC (4 within enclosure); 40AH/65AH (requires separate enclosure).
* Type: Sealed lead acid or gel type.
* Failover: Upon AC loss, instantaneous.
Visual Indicators
* Red LEDs indicate outputs are triggered (relays energized).
* Green LED indicates FACP disconnect is triggered.
* AC input and DC output LED indicators.
Electrical
* Temperature:
* Operating: 0° C to 49° C (32° F to 120° F).
* Storage: - 20° C to 70° C ( - 4° F to 158° F).
* Relative Humidity: 85% +/- 5%.
* BTU/Hr. (approx.): 115 BTU/Hr.
* System AC input VA requirement: 483VA.
Altronix
MAXIMAL7